RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0802007370 - Archived data from Wed, 21. April 2021 14:03:44 CEST


This is all the information about APD 0802007370. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0802007370
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E04
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 388.2 V
Dark current: 3.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 190
Position in Box: 26
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 29. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 25. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 388.1048989 V     T = -25 °C: 351.9783975 V
Voltage for Gain 150: T = +20 °C: 396.0663876 V     T = -25 °C: 359.551455 V
Voltage for Gain 200: T = +20 °C: 400.4862587 V     T = -25 °C: 363.7896143 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.466345296 V-1     T = -25 °C: 4.757856064 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.648040092 V-1     T = -25 °C: 9.587534315 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.97021515 V-1     T = -25 °C: 14.90722704 V-1
Break-through voltage: T = +20 °C: 416.2011458 V     T = -25 °C: 379.6405559 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 09:35:27 CET oafedulidis Assigned to capsule by script
10. May 2021 14:01:02 CEST oafedulidis Updated box and position via API.
21. Apr 2021 14:03:44 CEST jreher Updated box and position via API.
21. Apr 2021 13:59:48 CEST jreher Updated box and position via API.
05. Feb 2021 11:12:52 CET jreher Updated box and position via API.
11. Aug 2020 17:34:52 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:02:40 CET jreher Updated APD location via API.
25. Nov 2019 17:25:51 CET jreher Updated box and position via API.
16. Aug 2019 10:43:32 CEST spankonin Updated APD batch assignment via API.
13. Aug 2019 12:10:57 CEST spankonin Updated APD location via API.
09. Aug 2019 17:00:10 CEST spankonin Updated APD batch assignment via API.
09. Aug 2019 14:33:55 CEST markus.moritz
22. Jun 2016 15:22:35 CEST Tobias Imported from Hamamatsu datasheet.