RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2709030693 - Archived data from Tue, 11. August 2020 17:38:27 CEST


This is all the information about APD 2709030693. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2709030693
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F11
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 387.5 V
Dark current: 15 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 81
Position in Box: 33
EP1 batch: 67
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.0595992 V     T = -25 °C: 351.2154729 V
Voltage for Gain 150: T = +20 °C: 394.8736361 V     T = -25 °C: 358.6622193 V
Voltage for Gain 200: T = +20 °C: 399.1936111 V     T = -25 °C: 362.8179721 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.62027344 V-1     T = -25 °C: 4.816717361 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.208672497 V-1     T = -25 °C: 9.821484127 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.49628716 V-1     T = -25 °C: 15.67898779 V-1
Break-through voltage: T = +20 °C: 413.9788989 V     T = -25 °C: 377.5312665 V
   
Notes:


Version history

Time Author Change comment
25. Oct 2021 14:40:23 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:01:13 CEST jreher Updated box and position via API.
05. Feb 2021 10:58:48 CET jreher Updated box and position via API.
03. Feb 2021 18:24:18 CET jreher Updated box and position via API.
11. Aug 2020 17:38:27 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:43:11 CET jreher Updated APD location via API.
25. Nov 2019 17:17:21 CET jreher Updated box and position via API.
10. Sep 2019 11:21:39 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 11:17:11 CEST markus.moritz
25. Jul 2019 12:13:45 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:03 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:27 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:04:15 CEST Tobias Imported from Hamamatsu datasheet.