RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2708030638 - Archived data from Wed, 03. February 2021 18:24:12 CET


This is all the information about APD 2708030638. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2708030638
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E03
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.4 V
Dark current: 10.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 80
Position in Box: 50
EP1 batch: 66
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.3769985 V     T = -25 °C: 345.9835072 V
Voltage for Gain 150: T = +20 °C: 389.2530278 V     T = -25 °C: 353.3900869 V
Voltage for Gain 200: T = +20 °C: 393.6231522 V     T = -25 °C: 357.5327027 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.443835296 V-1     T = -25 °C: 4.853225065 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.586832111 V-1     T = -25 °C: 9.018253836 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.85198446 V-1     T = -25 °C: 15.91277949 V-1
Break-through voltage: T = +20 °C: 409.1961781 V     T = -25 °C: 372.9018508 V
   
Notes:


Version history

Time Author Change comment
27. Oct 2021 14:25:11 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 16:57:54 CEST jreher Updated box and position via API.
05. Feb 2021 10:58:42 CET jreher Updated box and position via API.
03. Feb 2021 18:24:12 CET jreher Updated box and position via API.
11. Aug 2020 17:38:21 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:43:01 CET jreher Updated APD location via API.
25. Nov 2019 17:17:17 CET jreher Updated box and position via API.
10. Sep 2019 11:21:16 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 11:03:38 CEST markus.moritz
25. Jul 2019 12:13:58 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:57 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:26 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:04:11 CEST Tobias Imported from Hamamatsu datasheet.