RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2707030549 - Archived data from Fri, 05. February 2021 10:58:31 CET


This is all the information about APD 2707030549. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2707030549
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F12
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 385.8 V
Dark current: 10.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 79
Position in Box: 25
EP1 batch: 63
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 28. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.7496457 V     T = -25 °C: 350.0724232 V
Voltage for Gain 150: T = +20 °C: 393.5926658 V     T = -25 °C: 357.5634997 V
Voltage for Gain 200: T = +20 °C: 397.9366149 V     T = -25 °C: 361.7491453 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.670551515 V-1     T = -25 °C: 4.811513494 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.303509536 V-1     T = -25 °C: 9.724615489 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.54228403 V-1     T = -25 °C: 15.42748424 V-1
Break-through voltage: T = +20 °C: 412.2681217 V     T = -25 °C: 376.2620197 V
   
Notes:


Version history

Time Author Change comment
14. Apr 2021 14:20:32 CEST jreher Assigned to capsule by script
16. Feb 2021 12:28:31 CET jreher Updated box and position via API.
05. Feb 2021 10:58:31 CET jreher Updated box and position via API.
03. Feb 2021 18:24:01 CET jreher Updated box and position via API.
11. Aug 2020 17:38:07 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:42:48 CET jreher Updated APD location via API.
25. Nov 2019 17:17:11 CET jreher Updated box and position via API.
10. Sep 2019 11:19:59 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 10:28:03 CEST markus.moritz
25. Jul 2019 12:14:41 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:47 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:23 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:03:35 CEST Tobias Imported from Hamamatsu datasheet.