RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2705030362 - Archived data from Wed, 03. February 2021 18:23:45 CET


This is all the information about APD 2705030362. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2705030362
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2705030362/2303024388
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: C09
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 384.3 V
Dark current: 12.2 nA
   
Screening Logistics:  
Available: No
Storage Box: 77
Position in Box: 18
EP1 batch: 60
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.4811679 V     T = -25 °C: 348.9210616 V
Voltage for Gain 150: T = +20 °C: 392.3416893 V     T = -25 °C: 356.367828 V
Voltage for Gain 200: T = +20 °C: 396.7102231 V     T = -25 °C: 360.5489466 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.461083647 V-1     T = -25 °C: 4.918611974 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.697770915 V-1     T = -25 °C: 9.147474886 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.22601783 V-1     T = -25 °C: 16.23965568 V-1
Break-through voltage: T = +20 °C: 412.4451187 V     T = -25 °C: 376.0281412 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:58:12 CET jreher Updated box and position via API.
03. Feb 2021 18:23:45 CET jreher Updated box and position via API.
29. Jan 2021 10:25:29 CET jreher Assigned to capsule by script
06. Oct 2020 16:50:48 CEST jreher Updated box and position via API.
11. Aug 2020 17:37:50 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:42:25 CET jreher Updated APD location via API.
25. Nov 2019 17:17:01 CET jreher Updated box and position via API.
06. Sep 2019 13:12:51 CEST spankonin Updated APD batch assignment via API.
03. Sep 2019 14:29:55 CEST markus.moritz
08. Jul 2019 14:56:12 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:30 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:19 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:02:50 CEST Tobias Imported from Hamamatsu datasheet.