Show Hamamatsu Avalanche Photo Diode 2704030310 - Archived data from Fri, 27. August 2021 11:14:04 CEST
This is all the information about APD 2704030310. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2704030310 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | D07 |
| Break-through voltage: | 411 V |
| Voltage for Gain 100 (T=+25°C): | 383.3 V |
| Dark current: | 14.9 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 76 |
| Position in Box: | 37 |
| EP1 batch: | 59 |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 26. Aug 2019 |
| Sent for analysis after irradiation: | 02. Sep 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 28. Aug 2019 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 31. Aug 2019 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 383.7376819 V T = -25 °C: 348.4802053 V |
| Voltage for Gain 150: | T = +20 °C: 391.5829427 V T = -25 °C: 355.8249471 V |
| Voltage for Gain 200: | T = +20 °C: 395.9305276 V T = -25 °C: 359.9383051 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.690058048 V-1 T = -25 °C: 4.755999593 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.328414453 V-1 T = -25 °C: 9.664228001 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.60023392 V-1 T = -25 °C: 15.47275633 V-1 |
| Break-through voltage: | T = +20 °C: 410.602281 V T = -25 °C: 374.2204933 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 27. Jun 2022 12:43:45 CEST | oafedulidis | Assigned to capsule by script |
| 27. Aug 2021 11:14:04 CEST | oafedulidis | Updated box and position via API. |
| 05. Feb 2021 10:58:07 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:23:39 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:37:44 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:42:16 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:16:57 CET | jreher | Updated box and position via API. |
| 06. Sep 2019 13:12:09 CEST | spankonin | Updated APD batch assignment via API. |
| 03. Sep 2019 12:31:37 CEST | markus.moritz | |
| 08. Jul 2019 14:55:57 CEST | spankonin | Updated APD batch assignment via API. |
| 05. Jul 2019 13:46:23 CEST | jreher | Updated APD location via API. |
| 03. Jan 2019 00:13:18 CET | Tobias | Corrected dark current unit. |
| 24. May 2018 14:39:23 CEST | Tobias | Updated location to "Bochum". |
| 18. May 2018 12:02:39 CEST | Tobias | Imported from Hamamatsu datasheet. |