Show Hamamatsu Avalanche Photo Diode 2704030298 - Archived data from Fri, 05. July 2019 13:46:23 CEST
This is all the information about APD 2704030298. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2704030298 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum Box 76 |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | E09 |
| Break-through voltage: | 407 V |
| Voltage for Gain 100 (T=+25°C): | 378.2 V |
| Dark current: | 14.8 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 76 |
| Position in Box: | 33 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | none |
| Sent for analysis after irradiation: | none |
| Return for assembly: | none |
| Irradiation: | |
| Date: | none |
| Dose used: | none |
| Temperature: | none |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 10:58:06 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:23:39 CET | jreher | Updated box and position via API. |
| 07. Oct 2020 12:12:53 CEST | jreher | Assigned to capsule by script |
| 17. Aug 2020 15:53:25 CEST | jreher | Updated box and position via API. |
| 11. Aug 2020 17:37:43 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:42:15 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:16:57 CET | jreher | Updated box and position via API. |
| 06. Sep 2019 13:12:09 CEST | spankonin | Updated APD batch assignment via API. |
| 03. Sep 2019 12:28:49 CEST | markus.moritz | |
| 08. Jul 2019 14:55:56 CEST | spankonin | Updated APD batch assignment via API. |
| 05. Jul 2019 13:46:23 CEST | jreher | Updated APD location via API. |
| 03. Jan 2019 00:13:18 CET | Tobias | Corrected dark current unit. |
| 24. May 2018 14:39:23 CEST | Tobias | Updated location to "Bochum". |
| 18. May 2018 12:02:37 CEST | Tobias | Imported from Hamamatsu datasheet. |