Subdetector specification:  
Serial: 2703030210
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C06
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.4 V
Dark current: 8.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 178
Position in Box: 46
EP1 batch: 58
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.6476914 V     T = -25 °C: 344.4617469 V
Voltage for Gain 150: T = +20 °C: 387.4937249 V     T = -25 °C: 351.8221618 V
Voltage for Gain 200: T = +20 °C: 391.8529091 V     T = -25 °C: 355.9277288 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.405923018 V-1     T = -25 °C: 4.530473286 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.575754113 V-1     T = -25 °C: 9.628828138 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.80225509 V-1     T = -25 °C: 15.60848292 V-1
Break-through voltage: T = +20 °C: 407.3814993 V     T = -25 °C: 371.0351381 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 09:41:59 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:02:38 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:58:56 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:51:45 CEST oafedulidis Updated box and position via API.
03. May 2021 10:24:50 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:57:58 CET jreher Updated box and position via API.
03. Feb 2021 18:23:31 CET jreher Updated box and position via API.
11. Aug 2020 17:37:34 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:42:04 CET jreher Updated APD location via API.
25. Nov 2019 17:16:52 CET jreher Updated box and position via API.
06. Sep 2019 13:11:42 CEST spankonin Updated APD batch assignment via API.
03. Sep 2019 11:47:43 CEST markus.moritz
08. Jul 2019 14:55:40 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:15 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:16 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:02:18 CEST Tobias Imported from Hamamatsu datasheet.