Show Hamamatsu Avalanche Photo Diode 2701030049 - Archived data from Tue, 11. August 2020 17:37:18 CEST


This is all the information about APD 2701030049. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2701030049
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G12
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 390.6 V
Dark current: 8.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 73
Position in Box: 46
EP1 batch: 55
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 390.0417348 V     T = -25 °C: 354.1296198 V
Voltage for Gain 150: T = +20 °C: 397.844567 V     T = -25 °C: 361.6435751 V
Voltage for Gain 200: T = +20 °C: 402.1587069 V     T = -25 °C: 365.8318698 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.6115151 V-1     T = -25 °C: 4.828823199 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.242932891 V-1     T = -25 °C: 9.72103754 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.51437105 V-1     T = -25 °C: 15.49436334 V-1
Break-through voltage: T = +20 °C: 416.2002228 V     T = -25 °C: 379.9494115 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:57:44 CET jreher Updated box and position via API.
03. Feb 2021 18:23:17 CET jreher Updated box and position via API.
11. Aug 2020 17:37:18 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:41:43 CET jreher Updated APD location via API.
25. Nov 2019 17:16:44 CET jreher Updated box and position via API.
06. Sep 2019 13:10:24 CEST spankonin Updated APD batch assignment via API.
02. Sep 2019 14:53:01 CEST markus.moritz
08. Jul 2019 14:54:40 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:00 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:13 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:01:49 CEST Tobias Imported from Hamamatsu datasheet.