RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2609029852 - Archived data from Fri, 05. February 2021 10:57:26 CET


This is all the information about APD 2609029852. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2609029852
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E08
Break-through voltage: 404 V
Voltage for Gain 100 (T=+25°C): 375.5 V
Dark current: 9.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 71
Position in Box: 20
EP1 batch: 51
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 375.6377385 V     T = -25 °C: 340.78052 V
Voltage for Gain 150: T = +20 °C: 383.435467 V     T = -25 °C: 348.0585866 V
Voltage for Gain 200: T = +20 °C: 387.7955667 V     T = -25 °C: 352.1497918 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.459995938 V-1     T = -25 °C: 5.083553921 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.637594231 V-1     T = -25 °C: 9.551700227 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.92012933 V-1     T = -25 °C: 15.17743987 V-1
Break-through voltage: T = +20 °C: 403.3066273 V     T = -25 °C: 367.1515194 V
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 13:06:40 CET oafedulidis Assigned to capsule by script
01. Dec 2021 12:56:33 CET oafedulidis Updated box and position via API.
05. Feb 2021 10:57:26 CET jreher Updated box and position via API.
03. Feb 2021 18:22:59 CET jreher Updated box and position via API.
11. Aug 2020 17:36:57 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:41:19 CET jreher Updated APD location via API.
25. Nov 2019 17:16:31 CET jreher Updated box and position via API.
06. Sep 2019 13:08:19 CEST spankonin Updated APD batch assignment via API.
02. Sep 2019 10:48:28 CEST markus.moritz
08. Jul 2019 14:53:36 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:45:43 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:08 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:01:23 CEST Tobias Imported from Hamamatsu datasheet.