RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2608029778 - Archived data from Mon, 17. August 2020 15:54:06 CEST


This is all the information about APD 2608029778. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2608029778
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C05
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.6 V
Dark current: 8.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 70
Position in Box: 18
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 24. Jul 2018
Sent for analysis after irradiation: 21. Aug 2018
Return for assembly: none
   
Irradiation:  
Date: 16. Aug 2018
Dose used: 30 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Aug 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.6292065 V     T = -25 °C: 344.245972 V
Voltage for Gain 150: T = +20 °C: 387.467032 V     T = -25 °C: 351.635955 V
Voltage for Gain 200: T = +20 °C: 391.8568987 V     T = -25 °C: 355.7968754 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.740855901 V-1     T = -25 °C: 4.824592651 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.130323389 V-1     T = -25 °C: 9.610460649 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.34692701 V-1     T = -25 °C: 15.66815863 V-1
Break-through voltage: T = +20 °C: 407.6399241 V     T = -25 °C: 371.2269164 V
   
Notes: foam


Version history

Time Author Change comment
05. Feb 2021 10:57:21 CET jreher Updated box and position via API.
03. Feb 2021 18:22:54 CET jreher Updated box and position via API.
07. Oct 2020 12:19:04 CEST jreher Assigned to capsule by script
17. Aug 2020 15:54:06 CEST jreher Updated box and position via API.
11. Aug 2020 17:26:46 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:36:39 CET jreher Updated APD location via API.
25. Nov 2019 17:16:26 CET jreher Updated box and position via API.
25. Nov 2019 17:14:22 CET jreher Updated box and position via API.
04. Jul 2019 11:11:29 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:39 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:36 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:13:07 CET Tobias Corrected dark current unit.
21. Aug 2018 11:52:32 CEST markus.moritz
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:01:05 CEST Tobias Imported from Hamamatsu datasheet.