Show Hamamatsu Avalanche Photo Diode 2520029099 - Archived data from Fri, 13. September 2019 10:31:35 CEST
					This is all the information about APD 2520029099. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2520029099 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | Bochum Box 69 | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | A09 | 
| Break-through voltage: | 411 V | 
| Voltage for Gain 100 (T=+25°C): | 382.8 V | 
| Dark current: | 3.7 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 69 | 
| Position in Box: | 6 | 
| EP1 batch: | 49 | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | none | 
| Position in grid: | none | 
| Arrival for irradiation: | 16. Jul 2019 | 
| Sent for analysis after irradiation: | 19. Jul 2019 | 
| Return for assembly: | none | 
| Irradiation: | |
| Date: | 16. Jul 2019 | 
| Dose used: | 37 Gy | 
| Temperature: | 20 °C | 
| Position: | none | 
| Bias voltage: | none | 
| Annealing: | |
| Date: | 17. Jul 2019 | 
| Temperature: | 80 °C | 
| Duration: | 48 h | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none | 
| Break-through voltage: | T = +20 °C: none T = -25 °C: none | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 29. Apr 2021 17:04:41 CEST | oafedulidis | Assigned to capsule by script | 
| 16. Feb 2021 12:26:10 CET | jreher | Updated box and position via API. | 
| 05. Feb 2021 10:57:13 CET | jreher | Updated box and position via API. | 
| 03. Feb 2021 18:22:45 CET | jreher | Updated box and position via API. | 
| 11. Aug 2020 17:39:42 CEST | jreher | Updated APD characteristics via API. | 
| 27. Nov 2019 19:40:59 CET | jreher | Updated APD location via API. | 
| 25. Nov 2019 17:16:20 CET | jreher | Updated box and position via API. | 
| 13. Sep 2019 10:31:35 CEST | jgrochowski | Updated APD batch assignment via API. | 
| 29. Jul 2019 14:26:51 CEST | markus.moritz | |
| 08. Jul 2019 14:53:05 CEST | spankonin | Updated APD batch assignment via API. | 
| 05. Jul 2019 13:45:27 CEST | jreher | Updated APD location via API. | 
| 03. Jan 2019 00:13:05 CET | Tobias | Corrected dark current unit. | 
| 24. May 2018 14:39:23 CEST | Tobias | Updated location to "Bochum". | 
| 18. May 2018 12:00:39 CEST | Tobias | Imported from Hamamatsu datasheet. | 
 
						 
					