RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2520029097 - Archived data from Wed, 28. April 2021 13:27:30 CEST


This is all the information about APD 2520029097. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2520029097
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G09
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 377.5 V
Dark current: 6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 69
Position in Box: 4
EP1 batch: 49
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.1252571 V     T = -25 °C: 342.1539964 V
Voltage for Gain 150: T = +20 °C: 384.9698836 V     T = -25 °C: 349.5042569 V
Voltage for Gain 200: T = +20 °C: 389.362376 V     T = -25 °C: 353.606402 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.575612958 V-1     T = -25 °C: 4.89576192 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.99540388 V-1     T = -25 °C: 9.094779782 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.88262904 V-1     T = -25 °C: 16.27284192 V-1
Break-through voltage: T = +20 °C: 405.2714534 V     T = -25 °C: 369.0335541 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 10:25:38 CEST oafedulidis Assigned to capsule by script
28. Apr 2021 13:27:30 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:57:13 CET jreher Updated box and position via API.
03. Feb 2021 18:22:45 CET jreher Updated box and position via API.
11. Aug 2020 17:39:41 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:40:59 CET jreher Updated APD location via API.
25. Nov 2019 17:16:20 CET jreher Updated box and position via API.
13. Sep 2019 10:31:35 CEST jgrochowski Updated APD batch assignment via API.
29. Jul 2019 14:25:39 CEST markus.moritz
08. Jul 2019 14:53:04 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:45:27 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:05 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:00:38 CEST Tobias Imported from Hamamatsu datasheet.