RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2410026686 - Archived data from Tue, 11. August 2020 17:22:06 CEST


This is all the information about APD 2410026686. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2410026686
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B09
Break-through voltage: 416 V
Voltage for Gain 100 (T=+25°C): 387.4 V
Dark current: 6.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 174
Position in Box: 46
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 388.2340286 V     T = -25 °C: 352.3864042 V
Voltage for Gain 150: T = +20 °C: 396.0875458 V     T = -25 °C: 359.9315924 V
Voltage for Gain 200: T = +20 °C: 400.4645989 V     T = -25 °C: 364.1616488 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.658711662 V-1     T = -25 °C: 4.851442825 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.073489761 V-1     T = -25 °C: 9.563120625 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.2810697 V-1     T = -25 °C: 14.50580447 V-1
Break-through voltage: T = +20 °C: 414.8615476 V     T = -25 °C: 378.6265935 V
   
Notes: foam


Version history

Time Author Change comment
26. Apr 2021 15:23:01 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:49:35 CET jreher Updated box and position via API.
03. Feb 2021 18:15:45 CET jreher Updated box and position via API.
11. Aug 2020 17:22:06 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:31:54 CET jreher Updated APD location via API.
25. Nov 2019 17:12:01 CET jreher Updated box and position via API.
04. Jul 2019 11:08:08 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:29 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:24 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:03:36 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:13:02 CET Tobias Corrected dark current unit.
26. Nov 2018 12:20:21 CET markus.moritz
16. Nov 2018 12:25:00 CET markus.moritz
12. Jan 2018 13:16:57 CET Tobias Imported from Hamamatsu datasheet.