RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2409026594 - Archived data from Fri, 27. August 2021 10:29:19 CEST


This is all the information about APD 2409026594. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2409026594
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E13
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.2 V
Dark current: 6.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 13
Position in Box: 25
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.1681688 V     T = -25 °C: 344.0128728 V
Voltage for Gain 150: T = +20 °C: 386.9981826 V     T = -25 °C: 351.4168878 V
Voltage for Gain 200: T = +20 °C: 391.372959 V     T = -25 °C: 355.597325 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.571634309 V-1     T = -25 °C: 4.806948375 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.071311357 V-1     T = -25 °C: 9.45593165 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.09438882 V-1     T = -25 °C: 14.5169885 V-1
Break-through voltage: T = +20 °C: 407.1432932 V     T = -25 °C: 370.7315874 V
   
Notes: foam


Version history

Time Author Change comment
27. Jun 2022 12:42:08 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 10:29:19 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:49:26 CET jreher Updated box and position via API.
03. Feb 2021 18:15:35 CET jreher Updated box and position via API.
11. Aug 2020 17:21:53 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:31:42 CET jreher Updated APD location via API.
25. Nov 2019 17:11:55 CET jreher Updated box and position via API.
04. Jul 2019 11:07:58 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:22 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:18 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:03:18 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:13:00 CET Tobias Corrected dark current unit.
26. Nov 2018 13:42:39 CET markus.moritz
16. Nov 2018 15:28:42 CET markus.moritz
12. Jan 2018 13:16:55 CET Tobias Imported from Hamamatsu datasheet.