Show Hamamatsu Avalanche Photo Diode 2409026582 - Archived data from Wed, 12. June 2019 16:31:17 CEST
This is all the information about APD 2409026582. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2409026582 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | unknown |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | D03 |
| Break-through voltage: | 414 V |
| Voltage for Gain 100 (T=+25°C): | 385 V |
| Dark current: | 4.2 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 13 |
| Position in Box: | 14 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 12. Nov 2018 |
| Sent for analysis after irradiation: | 26. Nov 2018 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 22. Nov 2018 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 23. Nov 2018 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: | foam |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 10:49:25 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:15:34 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:21:51 CEST | jreher | Updated APD characteristics via API. |
| 31. Mar 2020 08:49:37 CEST | jreher | Assigned to capsule by script |
| 13. Feb 2020 15:11:37 CET | jreher | Updated box and position via API. |
| 27. Nov 2019 19:31:41 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:11:54 CET | jreher | Updated box and position via API. |
| 04. Jul 2019 11:07:58 CEST | jreher | Updated APD location via API. |
| 12. Jun 2019 16:46:22 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 16:31:17 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 15:03:17 CEST | jreher | Updated APD batch assignment via API. |
| 03. Jan 2019 00:12:59 CET | Tobias | Corrected dark current unit. |
| 26. Nov 2018 13:49:31 CET | markus.moritz | |
| 16. Nov 2018 15:32:28 CET | markus.moritz | |
| 12. Jan 2018 13:16:55 CET | Tobias | Imported from Hamamatsu datasheet. |