RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2407026438 - Archived data from Tue, 11. August 2020 17:21:31 CEST


This is all the information about APD 2407026438. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2407026438
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C12
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.1 V
Dark current: 4.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 353
Position in Box: 42
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 13. Dec 2018
Return for assembly: none
   
Irradiation:  
Date: 07. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.2208517 V     T = -25 °C: 346.1149289 V
Voltage for Gain 150: T = +20 °C: 389.0408601 V     T = -25 °C: 353.4969771 V
Voltage for Gain 200: T = +20 °C: 393.4080755 V     T = -25 °C: 357.6292166 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.549208932 V-1     T = -25 °C: 4.889884518 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.991321056 V-1     T = -25 °C: 9.08823807 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.86997612 V-1     T = -25 °C: 16.08593163 V-1
Break-through voltage: T = +20 °C: 409.2511491 V     T = -25 °C: 373.1758293 V
   
Notes:


Version history

Time Author Change comment
27. Jun 2022 12:42:41 CEST oafedulidis Assigned to capsule by script
16. Jun 2021 16:03:55 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:10 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:52:50 CEST oafedulidis Updated box and position via API.
21. Apr 2021 14:47:15 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:49:09 CET jreher Updated box and position via API.
03. Feb 2021 18:15:17 CET jreher Updated box and position via API.
11. Aug 2020 17:21:31 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:31:19 CET jreher Updated APD location via API.
25. Nov 2019 17:11:44 CET jreher Updated box and position via API.
04. Jul 2019 11:07:41 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:12 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:07 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:02:44 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:56 CET Tobias Corrected dark current unit.
13. Dec 2018 13:31:18 CET markus.moritz
30. Nov 2018 13:45:52 CET markus.moritz
12. Jan 2018 13:16:53 CET Tobias Imported from Hamamatsu datasheet.