RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2405026301 - Archived data from Fri, 05. February 2021 10:48:58 CET


This is all the information about APD 2405026301. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2405026301
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G12
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382.2 V
Dark current: 5.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 9
Position in Box: 47
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 13. Dec 2018
Return for assembly: none
   
Irradiation:  
Date: 07. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.9791093 V     T = -25 °C: 346.7521148 V
Voltage for Gain 150: T = +20 °C: 389.8345013 V     T = -25 °C: 354.16404 V
Voltage for Gain 200: T = +20 °C: 394.2023613 V     T = -25 °C: 358.3301514 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.619555069 V-1     T = -25 °C: 4.629295027 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.177496646 V-1     T = -25 °C: 9.357548168 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.37120163 V-1     T = -25 °C: 14.7691399 V-1
Break-through voltage: T = +20 °C: 409.0671355 V     T = -25 °C: 373.8276276 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 10:46:00 CET oafedulidis Assigned to capsule by script
17. May 2021 09:17:32 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:48:58 CET jreher Updated box and position via API.
03. Feb 2021 18:15:06 CET jreher Updated box and position via API.
11. Aug 2020 17:21:17 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:31:00 CET jreher Updated APD location via API.
25. Nov 2019 17:11:38 CET jreher Updated box and position via API.
04. Jul 2019 11:06:04 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:06 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:01 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:02:27 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:52 CET Tobias Corrected dark current unit.
13. Dec 2018 14:06:06 CET markus.moritz
23. Nov 2018 11:56:34 CET markus.moritz
12. Jan 2018 13:16:51 CET Tobias Imported from Hamamatsu datasheet.