RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2405026272 - Archived data from Wed, 03. February 2021 18:15:03 CET


This is all the information about APD 2405026272. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2405026272
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2405026272/2416027217
Unit: #858 (barcode 1309009411)
Preamp: 4335
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: E07
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381 V
Dark current: 4.2 nA
   
Screening Logistics:  
Available: No
Storage Box: 9
Position in Box: 19
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 13. Dec 2018
Return for assembly: none
   
Irradiation:  
Date: 07. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.0861325 V     T = -25 °C: 345.6593661 V
Voltage for Gain 150: T = +20 °C: 388.9308533 V     T = -25 °C: 353.0738777 V
Voltage for Gain 200: T = +20 °C: 393.3341864 V     T = -25 °C: 357.2167695 V
Gain/Voltage slope at M = 100: T = +20 °C: 5.111200711 V-1     T = -25 °C: 4.657979203 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.685502687 V-1     T = -25 °C: 9.22156687 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.48293366 V-1     T = -25 °C: 14.11929207 V-1
Break-through voltage: T = +20 °C: 409.2083173 V     T = -25 °C: 372.7828625 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:48:55 CET jreher Updated box and position via API.
03. Feb 2021 18:15:03 CET jreher Updated box and position via API.
11. Aug 2020 17:21:12 CEST jreher Updated APD characteristics via API.
13. Feb 2020 14:42:51 CET jreher Updated box and position via API.
27. Nov 2019 19:30:58 CET jreher Updated APD location via API.
25. Nov 2019 17:11:36 CET jreher Updated box and position via API.
17. Oct 2019 14:06:18 CEST tholtmann Assigned to unit by script
17. Oct 2019 13:48:21 CEST tholtmann Assigned to capsule by script
04. Jul 2019 11:06:01 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:04 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:59 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:02:18 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:51 CET Tobias Corrected dark current unit.
13. Dec 2018 13:57:40 CET markus.moritz
23. Nov 2018 12:04:02 CET markus.moritz
12. Jan 2018 13:16:50 CET Tobias Imported from Hamamatsu datasheet.