RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2404026201 - Archived data from Tue, 11. August 2020 17:21:02 CEST


This is all the information about APD 2404026201. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2404026201
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2404026166/2404026201
Unit: #1011 (barcode 1309009534)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: E09
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.1 V
Dark current: 3.6 nA
   
Screening Logistics:  
Available: No
Storage Box: 8
Position in Box: 20
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.1837064 V     T = -25 °C: 345.7342415 V
Voltage for Gain 150: T = +20 °C: 389.0340058 V     T = -25 °C: 353.1140064 V
Voltage for Gain 200: T = +20 °C: 393.4203987 V     T = -25 °C: 357.2558128 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.573816748 V-1     T = -25 °C: 4.679059745 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.99596154 V-1     T = -25 °C: 9.47096997 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.96851161 V-1     T = -25 °C: 14.9824045 V-1
Break-through voltage: T = +20 °C: 409.0911154 V     T = -25 °C: 372.5173326 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:48:44 CET jreher Updated box and position via API.
03. Feb 2021 18:14:55 CET jreher Updated box and position via API.
11. Aug 2020 17:21:02 CEST jreher Updated APD characteristics via API.
31. Mar 2020 08:44:10 CEST jreher Assigned to capsule by script
13. Feb 2020 15:25:31 CET jreher Updated box and position via API.
27. Nov 2019 19:30:47 CET jreher Updated APD location via API.
25. Nov 2019 17:11:31 CET jreher Updated box and position via API.
04. Jul 2019 11:05:53 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:00 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:55 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:01:53 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:49 CET Tobias Corrected dark current unit.
26. Nov 2018 12:17:03 CET markus.moritz
26. Nov 2018 11:16:06 CET markus.moritz
26. Nov 2018 11:15:46 CET markus.moritz
16. Nov 2018 11:53:46 CET markus.moritz
12. Jan 2018 13:16:49 CET Tobias Imported from Hamamatsu datasheet.