RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2404026197 - Archived data from Wed, 03. February 2021 18:14:55 CET


This is all the information about APD 2404026197. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2404026197
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2401025909/2404026197
Unit: #864 (barcode 1309009473)
Preamp: 4693
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: F04
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 379.9 V
Dark current: 3.1 nA
   
Screening Logistics:  
Available: No
Storage Box: 8
Position in Box: 16
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.9413313 V     T = -25 °C: 344.7611655 V
Voltage for Gain 150: T = +20 °C: 387.8331904 V     T = -25 °C: 352.1782122 V
Voltage for Gain 200: T = +20 °C: 392.2383406 V     T = -25 °C: 356.3587694 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.626884866 V-1     T = -25 °C: 4.642872605 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.157908065 V-1     T = -25 °C: 9.343708312 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.17276755 V-1     T = -25 °C: 14.74623912 V-1
Break-through voltage: T = +20 °C: 407.8442247 V     T = -25 °C: 371.7111713 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:48:43 CET jreher Updated box and position via API.
03. Feb 2021 18:14:55 CET jreher Updated box and position via API.
11. Aug 2020 17:21:01 CEST jreher Updated APD characteristics via API.
13. Feb 2020 14:42:52 CET jreher Updated box and position via API.
27. Nov 2019 19:30:47 CET jreher Updated APD location via API.
25. Nov 2019 17:11:31 CET jreher Updated box and position via API.
17. Oct 2019 14:10:11 CEST tholtmann Assigned to unit by script
17. Oct 2019 13:55:33 CEST tholtmann Assigned to capsule by script
04. Jul 2019 11:05:53 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:59 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:54 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:01:53 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:49 CET Tobias Corrected dark current unit.
26. Nov 2018 12:18:44 CET markus.moritz
26. Nov 2018 11:25:20 CET markus.moritz
16. Nov 2018 11:55:09 CET markus.moritz
12. Jan 2018 13:16:49 CET Tobias Imported from Hamamatsu datasheet.