RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2404026188 - Archived data from Wed, 03. February 2021 18:14:54 CET


This is all the information about APD 2404026188. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2404026188
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2404026188/2417027290
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: C03
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382 V
Dark current: 4.2 nA
   
Screening Logistics:  
Available: No
Storage Box: 8
Position in Box: 8
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.8202447 V     T = -25 °C: 346.6578647 V
Voltage for Gain 150: T = +20 °C: 389.715876 V     T = -25 °C: 354.0518741 V
Voltage for Gain 200: T = +20 °C: 394.1421857 V     T = -25 °C: 358.273686 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.470481502 V-1     T = -25 °C: 5.189200426 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.777567472 V-1     T = -25 °C: 9.303857082 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.41332038 V-1     T = -25 °C: 14.63228706 V-1
Break-through voltage: T = +20 °C: 410.2196359 V     T = -25 °C: 374.0901489 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:48:42 CET jreher Updated box and position via API.
03. Feb 2021 18:14:54 CET jreher Updated box and position via API.
11. Aug 2020 17:20:59 CEST jreher Updated APD characteristics via API.
27. Mar 2020 11:32:40 CET jreher Assigned to capsule by script
13. Feb 2020 15:25:41 CET jreher Updated box and position via API.
27. Nov 2019 19:30:46 CET jreher Updated APD location via API.
25. Nov 2019 17:11:30 CET jreher Updated box and position via API.
04. Jul 2019 11:05:53 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:58 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:53 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:01:21 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:49 CET Tobias Corrected dark current unit.
26. Sep 2018 11:34:36 CEST markus.moritz
12. Jan 2018 13:16:49 CET Tobias Imported from Hamamatsu datasheet.