RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2403026129 - Archived data from Tue, 11. August 2020 17:20:51 CEST


This is all the information about APD 2403026129. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2403026129
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F06
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 381.5 V
Dark current: 5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 7
Position in Box: 13
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: 02. Oct 2018
Return for assembly: none
   
Irradiation:  
Date: 27. Sep 2018
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: 28. Sep 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.3398417 V     T = -25 °C: 345.9186399 V
Voltage for Gain 150: T = +20 °C: 389.1488261 V     T = -25 °C: 353.2902921 V
Voltage for Gain 200: T = +20 °C: 393.49575 V     T = -25 °C: 357.4370735 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.530113282 V-1     T = -25 °C: 4.970601712 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.911715653 V-1     T = -25 °C: 9.234404426 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.68126891 V-1     T = -25 °C: 14.53766251 V-1
Break-through voltage: T = +20 °C: 409.161151 V     T = -25 °C: 372.9209079 V
   
Notes:


Version history

Time Author Change comment
25. Oct 2021 14:14:21 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:01:07 CEST jreher Updated box and position via API.
05. Feb 2021 10:48:29 CET jreher Updated box and position via API.
03. Feb 2021 18:14:46 CET jreher Updated box and position via API.
11. Aug 2020 17:20:51 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:30:36 CET jreher Updated APD location via API.
25. Nov 2019 17:11:26 CET jreher Updated box and position via API.
04. Jul 2019 11:05:45 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:54 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:49 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:01:11 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:47 CET Tobias Corrected dark current unit.
02. Oct 2018 14:34:47 CEST markus.moritz
26. Sep 2018 11:51:28 CEST markus.moritz
12. Jan 2018 13:16:48 CET Tobias Imported from Hamamatsu datasheet.