RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0724007227 - Archived data from Tue, 11. August 2020 17:35:35 CEST


This is all the information about APD 0724007227. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0724007227
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 0724007227/2308024813
Unit: #1208 (barcode 1309013272)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: F09
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382.4 V
Dark current: 11.1 nA
   
Screening Logistics:  
Available: No
Storage Box: 194
Position in Box: 43
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 29. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 25. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.5557419 V     T = -25 °C: 346.8875994 V
Voltage for Gain 150: T = +20 °C: 390.3400464 V     T = -25 °C: 354.1880001 V
Voltage for Gain 200: T = +20 °C: 394.6514406 V     T = -25 °C: 358.2939836 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.431415707 V-1     T = -25 °C: 4.986753414 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.663516577 V-1     T = -25 °C: 9.290996349 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.04253708 V-1     T = -25 °C: 16.56861311 V-1
Break-through voltage: T = +20 °C: 410.0968176 V     T = -25 °C: 373.454147 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:13:25 CET jreher Updated box and position via API.
11. Aug 2020 17:35:35 CEST jreher Updated APD characteristics via API.
03. Apr 2020 10:07:04 CEST jreher Assigned to capsule by script
20. Feb 2020 13:34:47 CET jreher Updated box and position via API.
27. Nov 2019 20:03:25 CET jreher Updated APD location via API.
25. Nov 2019 17:26:11 CET jreher Updated box and position via API.
16. Aug 2019 12:20:59 CEST jreher Updated APD location via API.
09. Aug 2019 17:01:44 CEST spankonin Updated APD batch assignment via API.
07. Aug 2019 13:55:10 CEST markus.moritz
22. Jun 2016 15:22:32 CEST Tobias Imported from Hamamatsu datasheet.