Show Hamamatsu Avalanche Photo Diode 2402026002 - Archived data from Thu, 04. July 2019 11:02:24 CEST
This is all the information about APD 2402026002. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2402026002 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | unknown |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | C14 |
| Break-through voltage: | 416 V |
| Voltage for Gain 100 (T=+25°C): | 387.9 V |
| Dark current: | 5.3 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 175 |
| Position in Box: | 37 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 24. Jul 2018 |
| Sent for analysis after irradiation: | 21. Aug 2018 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 16. Aug 2018 |
| Dose used: | 30 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 17. Aug 2018 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: | foam |
Version history
| Time | Author | Change comment |
|---|---|---|
| 26. Oct 2021 10:53:06 CEST | oafedulidis | Assigned to capsule by script |
| 28. Apr 2021 13:28:10 CEST | oafedulidis | Updated box and position via API. |
| 26. Apr 2021 14:30:38 CEST | oafedulidis | Updated box and position via API. |
| 05. Feb 2021 10:47:55 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:14:14 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:20:11 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:29:51 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:11:05 CET | jreher | Updated box and position via API. |
| 04. Jul 2019 11:04:28 CEST | jreher | Updated APD location via API. |
| 04. Jul 2019 11:04:17 CEST | jreher | Updated APD location via API. |
| 04. Jul 2019 11:02:58 CEST | jreher | Updated APD location via API. |
| 04. Jul 2019 11:02:24 CEST | jreher | Updated APD location via API. |
| 04. Jul 2019 10:44:12 CEST | jreher | Updated APD location via API. |
| 12. Jun 2019 16:45:35 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 16:30:30 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 16:30:11 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 14:58:45 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 14:56:13 CEST | jreher | Updated APD batch assignment via API. |
| 03. Jan 2019 00:12:44 CET | Tobias | Corrected dark current unit. |
| 21. Aug 2018 08:48:46 CEST | markus.moritz | |
| 20. Aug 2018 11:58:47 CEST | markus.moritz | |
| 12. Jan 2018 13:16:46 CET | Tobias | Imported from Hamamatsu datasheet. |