RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2401025942 - Archived data from Wed, 03. February 2021 18:14:38 CET


This is all the information about APD 2401025942. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2401025942
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2401025942/2515028685
Unit: #1282 (barcode 1309013531)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: E06
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.3 V
Dark current: 3.5 nA
   
Screening Logistics:  
Available: No
Storage Box: 6
Position in Box: 12
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: 02. Oct 2018
Return for assembly: none
   
Irradiation:  
Date: 27. Sep 2018
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: 28. Sep 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.2299754 V     T = -25 °C: 345.8172632 V
Voltage for Gain 150: T = +20 °C: 389.0481966 V     T = -25 °C: 353.2015161 V
Voltage for Gain 200: T = +20 °C: 393.3986478 V     T = -25 °C: 357.3487546 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.571111114 V-1     T = -25 °C: 5.027816574 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.081479417 V-1     T = -25 °C: 9.423876263 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.13431256 V-1     T = -25 °C: 14.85050354 V-1
Break-through voltage: T = +20 °C: 408.8995047 V     T = -25 °C: 372.8504261 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:48:19 CET jreher Updated box and position via API.
03. Feb 2021 18:14:38 CET jreher Updated box and position via API.
11. Aug 2020 17:20:40 CEST jreher Updated APD characteristics via API.
25. Jun 2020 11:26:04 CEST jreher Assigned to capsule by script
20. Feb 2020 13:34:36 CET jreher Updated box and position via API.
27. Nov 2019 19:30:25 CET jreher Updated APD location via API.
25. Nov 2019 17:11:21 CET jreher Updated box and position via API.
04. Jul 2019 11:05:37 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:49 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:45 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:00:54 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:42 CET Tobias Corrected dark current unit.
02. Oct 2018 15:11:42 CEST markus.moritz
26. Sep 2018 12:17:07 CEST markus.moritz
12. Jan 2018 13:16:45 CET Tobias Imported from Hamamatsu datasheet.