RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2401025941 - Archived data from Tue, 11. August 2020 17:20:40 CEST


This is all the information about APD 2401025941. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2401025941
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B05
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.5 V
Dark current: 4.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 6
Position in Box: 11
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: 02. Oct 2018
Return for assembly: none
   
Irradiation:  
Date: 27. Sep 2018
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: 28. Sep 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.38716 V     T = -25 °C: 347.8474444 V
Voltage for Gain 150: T = +20 °C: 391.2172564 V     T = -25 °C: 355.3110194 V
Voltage for Gain 200: T = +20 °C: 395.5811402 V     T = -25 °C: 359.5198331 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.489832509 V-1     T = -25 °C: 4.938623763 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.863235097 V-1     T = -25 °C: 9.112185722 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.51124734 V-1     T = -25 °C: 16.20576892 V-1
Break-through voltage: T = +20 °C: 409.0331173 V     T = -25 °C: 375.1737005 V
   
Notes:


Version history

Time Author Change comment
29. Mar 2022 12:35:51 CEST oafedulidis Assigned to capsule by script
17. May 2021 09:16:40 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:48:19 CET jreher Updated box and position via API.
03. Feb 2021 18:14:38 CET jreher Updated box and position via API.
11. Aug 2020 17:20:40 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:30:25 CET jreher Updated APD location via API.
25. Nov 2019 17:11:21 CET jreher Updated box and position via API.
04. Jul 2019 11:05:36 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:49 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:45 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:00:54 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:42 CET Tobias Corrected dark current unit.
02. Oct 2018 15:12:35 CEST markus.moritz
26. Sep 2018 12:17:34 CEST markus.moritz
12. Jan 2018 13:16:45 CET Tobias Imported from Hamamatsu datasheet.