RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2401025929 - Archived data from Fri, 05. February 2021 10:48:16 CET


This is all the information about APD 2401025929. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2401025929
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F05
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382.4 V
Dark current: 3.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 26
Position in Box: 49
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.179139 V     T = -25 °C: 346.6386489 V
Voltage for Gain 150: T = +20 °C: 390.0086688 V     T = -25 °C: 354.0724221 V
Voltage for Gain 200: T = +20 °C: 394.3581393 V     T = -25 °C: 358.2496594 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.556441822 V-1     T = -25 °C: 4.699975367 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.082607008 V-1     T = -25 °C: 9.484570732 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.24096787 V-1     T = -25 °C: 14.87632121 V-1
Break-through voltage: T = +20 °C: 409.6289837 V     T = -25 °C: 373.9064448 V
   
Notes:


Version history

Time Author Change comment
21. Apr 2021 14:49:16 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:48:16 CET jreher Updated box and position via API.
03. Feb 2021 18:14:35 CET jreher Updated box and position via API.
11. Aug 2020 17:20:38 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:30:16 CET jreher Updated APD location via API.
25. Nov 2019 17:11:19 CET jreher Updated box and position via API.
04. Jul 2019 11:05:31 CEST jreher Updated APD location via API.
04. Jul 2019 10:44:34 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:49 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:44 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:00:53 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:41 CET Tobias Corrected dark current unit.
26. Sep 2018 12:57:53 CEST markus.moritz
12. Jan 2018 13:16:45 CET Tobias Imported from Hamamatsu datasheet.