Show Hamamatsu Avalanche Photo Diode 2519029021 - Archived data from Fri, 18. December 2020 14:01:05 CET
This is all the information about APD 2519029021. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2519029021 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | E02 |
| Break-through voltage: | 407 V |
| Voltage for Gain 100 (T=+25°C): | 378.8 V |
| Dark current: | 4.7 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 67 |
| Position in Box: | 39 |
| EP1 batch: | 47 |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 16. Jul 2019 |
| Sent for analysis after irradiation: | 19. Jul 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 16. Jul 2019 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 17. Jul 2019 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 378.9086487 V T = -25 °C: 343.7565454 V |
| Voltage for Gain 150: | T = +20 °C: 386.7481673 V T = -25 °C: 351.1091229 V |
| Voltage for Gain 200: | T = +20 °C: 391.1253515 V T = -25 °C: 355.2598017 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.661120168 V-1 T = -25 °C: 5.042177475 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.192682774 V-1 T = -25 °C: 9.378706739 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.2456058 V-1 T = -25 °C: 14.74374065 V-1 |
| Break-through voltage: | T = +20 °C: 406.2628755 V T = -25 °C: 370.2083905 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 15. Feb 2021 15:39:23 CET | jreher | Assigned to capsule by script |
| 05. Feb 2021 10:57:00 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:22:34 CET | jreher | Updated box and position via API. |
| 18. Dec 2020 14:01:05 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:33:36 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:40:39 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:16:13 CET | jreher | Updated box and position via API. |
| 05. Aug 2019 16:54:48 CEST | jreher | Updated APD batch assignment via API. |
| 29. Jul 2019 13:30:06 CEST | markus.moritz | |
| 05. Jul 2019 13:45:13 CEST | jreher | Updated APD location via API. |
| 01. Jul 2019 12:45:59 CEST | jgrochowski | Updated APD batch assignment via API. |
| 03. Jan 2019 00:12:38 CET | Tobias | Corrected dark current unit. |
| 12. Jan 2018 13:12:16 CET | Tobias | Imported from Hamamatsu datasheet. |