RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2518028921 - Archived data from Tue, 11. August 2020 17:33:17 CEST


This is all the information about APD 2518028921. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2518028921
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D15
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 378.1 V
Dark current: 4.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 65
Position in Box: 43
EP1 batch: 44
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.8653534 V     T = -25 °C: 342.9057434 V
Voltage for Gain 150: T = +20 °C: 385.7178233 V     T = -25 °C: 350.2667658 V
Voltage for Gain 200: T = +20 °C: 390.1094198 V     T = -25 °C: 354.3944889 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.659790231 V-1     T = -25 °C: 4.969316169 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.121792874 V-1     T = -25 °C: 9.204469941 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.12905892 V-1     T = -25 °C: 16.36948147 V-1
Break-through voltage: T = +20 °C: 405.6560034 V     T = -25 °C: 369.4890819 V
   
Notes:


Version history

Time Author Change comment
29. Mar 2022 12:36:41 CEST oafedulidis Assigned to capsule by script
03. May 2021 15:20:57 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:56:44 CET jreher Updated box and position via API.
03. Feb 2021 18:22:19 CET jreher Updated box and position via API.
11. Aug 2020 17:33:17 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:40:17 CET jreher Updated APD location via API.
25. Nov 2019 17:16:04 CET jreher Updated box and position via API.
05. Aug 2019 16:49:40 CEST jreher Updated APD batch assignment via API.
25. Jul 2019 15:36:49 CEST markus.moritz
05. Jul 2019 13:44:58 CEST jreher Updated APD location via API.
01. Jul 2019 12:59:48 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:35 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:14 CET Tobias Imported from Hamamatsu datasheet.