RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2514028627 - Archived data from Mon, 17. August 2020 15:50:47 CEST


This is all the information about APD 2514028627. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2514028627
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G11
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 377.5 V
Dark current: 6.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 61
Position in Box: 4
EP1 batch: 36
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.7886422 V     T = -25 °C: 342.0705486 V
Voltage for Gain 150: T = +20 °C: 384.6040021 V     T = -25 °C: 349.3278122 V
Voltage for Gain 200: T = +20 °C: 388.9734136 V     T = -25 °C: 353.4052574 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.412787859 V-1     T = -25 °C: 5.150720915 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.719439786 V-1     T = -25 °C: 9.536666368 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.62545058 V-1     T = -25 °C: 15.75839839 V-1
Break-through voltage: T = +20 °C: 404.3308039 V     T = -25 °C: 368.4115781 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:56:10 CET jreher Updated box and position via API.
03. Feb 2021 18:21:43 CET jreher Updated box and position via API.
07. Oct 2020 12:17:44 CEST jreher Assigned to capsule by script
17. Aug 2020 15:50:47 CEST jreher Updated box and position via API.
11. Aug 2020 17:32:31 CEST jreher Updated APD characteristics via API.
20. Feb 2020 13:35:12 CET jreher Updated box and position via API.
27. Nov 2019 19:39:30 CET jreher Updated APD location via API.
25. Nov 2019 17:15:40 CET jreher Updated box and position via API.
01. Aug 2019 12:13:04 CEST spankonin Updated APD batch assignment via API.
24. Jul 2019 10:02:48 CEST markus.moritz
12. Jul 2019 13:55:37 CEST jreher Updated APD location via API.
01. Jul 2019 14:24:50 CEST spankonin Updated APD batch assignment via API.
03. Jan 2019 00:12:27 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:09 CET Tobias Imported from Hamamatsu datasheet.