This is all the information about APD 2513028547. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2513028547
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D03
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.1 V
Dark current: 7.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 181
Position in Box: 35
EP1 batch: 34
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.4273727 V     T = -25 °C: 344.9998355 V
Voltage for Gain 150: T = +20 °C: 387.4358675 V     T = -25 °C: 352.286348 V
Voltage for Gain 200: T = +20 °C: 391.9405613 V     T = -25 °C: 356.3988508 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.368958537 V-1     T = -25 °C: 5.38353306 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.659505355 V-1     T = -25 °C: 9.679105976 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.23073273 V-1     T = -25 °C: 15.46899364 V-1
Break-through voltage: T = +20 °C: 407.7755169 V     T = -25 °C: 371.2237246 V
   
Notes:


Version history

Time Author Change comment
09. Feb 2021 11:21:03 CET jreher Assigned to capsule by script
05. Feb 2021 11:11:40 CET jreher Updated box and position via API.
18. Dec 2020 13:59:26 CET jreher Updated box and position via API.
11. Aug 2020 17:32:18 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:01:02 CET jreher Updated APD location via API.
25. Nov 2019 17:25:09 CET jreher Updated box and position via API.
30. Jul 2019 15:19:58 CEST spankonin Updated APD batch assignment via API.
23. Jul 2019 15:28:50 CEST jreher Updated APD batch assignment via API.
05. Jul 2019 14:50:48 CEST jreher Updated APD location via API.
24. Jun 2019 16:06:48 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:25 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:08 CET Tobias Imported from Hamamatsu datasheet.