Show Hamamatsu Avalanche Photo Diode 2513028494 - Archived data from Mon, 25. November 2019 17:25:05 CET
					This is all the information about APD 2513028494. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2513028494 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | Bochum Box 180 | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | G05 | 
| Break-through voltage: | 405 V | 
| Voltage for Gain 100 (T=+25°C): | 376.9 V | 
| Dark current: | 6.9 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 180 | 
| Position in Box: | 34 | 
| EP1 batch: | 32 | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | none | 
| Position in grid: | none | 
| Arrival for irradiation: | 16. Jul 2019 | 
| Sent for analysis after irradiation: | 19. Jul 2019 | 
| Return for assembly: | none | 
| Irradiation: | |
| Date: | 16. Jul 2019 | 
| Dose used: | 37 Gy | 
| Temperature: | 20 °C | 
| Position: | none | 
| Bias voltage: | none | 
| Annealing: | |
| Date: | 17. Jul 2019 | 
| Temperature: | 80 °C | 
| Duration: | 48 h | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none | 
| Break-through voltage: | T = +20 °C: none T = -25 °C: none | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 05. Feb 2021 11:11:32 CET | jreher | Updated box and position via API. | 
| 11. Aug 2020 17:32:08 CEST | jreher | Updated APD characteristics via API. | 
| 27. Nov 2019 20:00:50 CET | jreher | Updated APD location via API. | 
| 25. Nov 2019 17:25:05 CET | jreher | Updated box and position via API. | 
| 30. Jul 2019 15:19:26 CEST | spankonin | Updated APD batch assignment via API. | 
| 23. Jul 2019 11:03:40 CEST | markus.moritz | |
| 05. Jul 2019 14:50:39 CEST | jreher | Updated APD location via API. | 
| 24. Jun 2019 16:13:11 CEST | jgrochowski | Updated APD batch assignment via API. | 
| 03. Jan 2019 00:12:23 CET | Tobias | Corrected dark current unit. | 
| 12. Jan 2018 13:12:07 CET | Tobias | Imported from Hamamatsu datasheet. | 
 
						 
					