Show Hamamatsu Avalanche Photo Diode 2512028434 - Archived data from Tue, 11. August 2020 17:32:00 CEST
This is all the information about APD 2512028434. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2512028434 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | E07 |
| Break-through voltage: | 406 V |
| Voltage for Gain 100 (T=+25°C): | 377.3 V |
| Dark current: | 7.1 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 179 |
| Position in Box: | 45 |
| EP1 batch: | 31 |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 16. Jul 2019 |
| Sent for analysis after irradiation: | 19. Jul 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 16. Jul 2019 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 17. Jul 2019 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 377.4425956 V T = -25 °C: 342.8985484 V |
| Voltage for Gain 150: | T = +20 °C: 385.2353806 V T = -25 °C: 350.3022756 V |
| Voltage for Gain 200: | T = +20 °C: 389.5919861 V T = -25 °C: 354.4890919 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.556355726 V-1 T = -25 °C: 4.978586395 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.931650044 V-1 T = -25 °C: 9.27424394 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 13.90054281 V-1 T = -25 °C: 14.52144889 V-1 |
| Break-through voltage: | T = +20 °C: 405.8089181 V T = -25 °C: 368.9326303 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:11:25 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:32:00 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 20:00:40 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:25:01 CET | jreher | Updated box and position via API. |
| 30. Jul 2019 15:19:11 CEST | spankonin | Updated APD batch assignment via API. |
| 23. Jul 2019 10:51:53 CEST | markus.moritz | |
| 05. Jul 2019 14:50:32 CEST | jreher | Updated APD location via API. |
| 24. Jun 2019 16:12:59 CEST | spankonin | Updated APD batch assignment via API. |
| 03. Jan 2019 00:12:21 CET | Tobias | Corrected dark current unit. |
| 12. Jan 2018 13:12:07 CET | Tobias | Imported from Hamamatsu datasheet. |