Show Hamamatsu Avalanche Photo Diode 2511028365 - Archived data from Mon, 25. November 2019 17:24:33 CET
This is all the information about APD 2511028365. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2511028365 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum Box 173 |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | B04 |
| Break-through voltage: | 411 V |
| Voltage for Gain 100 (T=+25°C): | 382.6 V |
| Dark current: | 6.9 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 173 |
| Position in Box: | 44 |
| EP1 batch: | 29 |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 16. Jul 2019 |
| Sent for analysis after irradiation: | 19. Jul 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 16. Jul 2019 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 17. Jul 2019 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:10:38 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:31:51 CEST | jreher | Updated APD characteristics via API. |
| 03. Apr 2020 09:46:51 CEST | jreher | Assigned to capsule by script |
| 13. Feb 2020 14:23:48 CET | jreher | Updated box and position via API. |
| 27. Nov 2019 19:59:34 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:24:33 CET | jreher | Updated box and position via API. |
| 30. Jul 2019 15:18:30 CEST | spankonin | Updated APD batch assignment via API. |
| 23. Jul 2019 10:25:49 CEST | markus.moritz | |
| 05. Jul 2019 13:59:10 CEST | jreher | Updated APD location via API. |
| 24. Jun 2019 16:14:39 CEST | spankonin | Updated APD batch assignment via API. |
| 03. Jan 2019 00:12:20 CET | Tobias | Corrected dark current unit. |
| 12. Jan 2018 13:12:06 CET | Tobias | Imported from Hamamatsu datasheet. |