RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2511028351 - Archived data from Mon, 15. February 2021 15:37:14 CET


This is all the information about APD 2511028351. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2511028351
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2511028351/2609029861
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: D02
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 381.9 V
Dark current: 6.4 nA
   
Screening Logistics:  
Available: No
Storage Box: 173
Position in Box: 30
EP1 batch: 29
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.1804617 V     T = -25 °C: 346.8524529 V
Voltage for Gain 150: T = +20 °C: 389.2447692 V     T = -25 °C: 354.2208503 V
Voltage for Gain 200: T = +20 °C: 393.7540825 V     T = -25 °C: 358.3602198 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.637602457 V-1     T = -25 °C: 4.69586338 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.837035483 V-1     T = -25 °C: 9.548171807 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.67092098 V-1     T = -25 °C: 15.52533007 V-1
Break-through voltage: T = +20 °C: 410.2499191 V     T = -25 °C: 374.0244975 V
   
Notes:


Version history

Time Author Change comment
16. Feb 2021 12:25:02 CET jreher Updated box and position via API.
15. Feb 2021 15:37:14 CET jreher Assigned to capsule by script
05. Feb 2021 11:10:37 CET jreher Updated box and position via API.
11. Aug 2020 17:31:48 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:59:33 CET jreher Updated APD location via API.
25. Nov 2019 17:24:31 CET jreher Updated box and position via API.
30. Jul 2019 15:18:16 CEST spankonin Updated APD batch assignment via API.
23. Jul 2019 10:21:53 CEST markus.moritz
05. Jul 2019 13:59:09 CEST jreher Updated APD location via API.
24. Jun 2019 16:14:38 CEST spankonin Updated APD batch assignment via API.
03. Jan 2019 00:12:19 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:06 CET Tobias Imported from Hamamatsu datasheet.