RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2507028019 - Archived data from Tue, 08. December 2020 17:17:22 CET


This is all the information about APD 2507028019. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2507028019
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 0915010086/2507028019
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: G08
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 385.9 V
Dark current: 7.5 nA
   
Screening Logistics:  
Available: No
Storage Box: 168
Position in Box: 17
EP1 batch: 20
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 02. Jul 2019
Sent for analysis after irradiation: 09. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 04. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 05. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.543115 V     T = -25 °C: 349.267844 V
Voltage for Gain 150: T = +20 °C: 392.5151293 V     T = -25 °C: 356.7751588 V
Voltage for Gain 200: T = +20 °C: 396.9290307 V     T = -25 °C: 360.9659555 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.552214219 V-1     T = -25 °C: 4.732372253 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.616508979 V-1     T = -25 °C: 8.882814909 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.65184383 V-1     T = -25 °C: 16.22022914 V-1
Break-through voltage: T = +20 °C: 412.2850078 V     T = -25 °C: 376.0646741 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:09:57 CET jreher Updated box and position via API.
08. Dec 2020 17:17:22 CET jreher Assigned to capsule by script
06. Oct 2020 16:52:03 CEST jreher Updated box and position via API.
11. Aug 2020 17:31:00 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:58:36 CET jreher Updated APD location via API.
25. Nov 2019 17:24:07 CET jreher Updated box and position via API.
30. Jul 2019 15:15:15 CEST spankonin Updated APD batch assignment via API.
09. Jul 2019 15:52:42 CEST markus.moritz
05. Jul 2019 13:58:27 CEST jreher Updated APD location via API.
24. Jun 2019 13:23:07 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:11 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:01 CET Tobias Imported from Hamamatsu datasheet.