Show Hamamatsu Avalanche Photo Diode 2505027922 - Archived data from Wed, 21. April 2021 11:03:11 CEST
This is all the information about APD 2505027922. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2505027922 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | E06 |
| Break-through voltage: | 407 V |
| Voltage for Gain 100 (T=+25°C): | 378.3 V |
| Dark current: | 4.5 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 176 |
| Position in Box: | 30 |
| EP1 batch: | 17 |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 02. Jul 2019 |
| Sent for analysis after irradiation: | 09. Jul 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 04. Jul 2019 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 05. Jul 2019 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 377.8397078 V T = -25 °C: 342.5688912 V |
| Voltage for Gain 150: | T = +20 °C: 385.7120932 V T = -25 °C: 349.995939 V |
| Voltage for Gain 200: | T = +20 °C: 390.1184505 V T = -25 °C: 354.1515484 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.426457911 V-1 T = -25 °C: 4.784293459 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.643933073 V-1 T = -25 °C: 9.853413776 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 15.11116084 V-1 T = -25 °C: 15.94398384 V-1 |
| Break-through voltage: | T = +20 °C: 406.3456803 V T = -25 °C: 369.7580692 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 25. Sep 2021 15:59:53 CEST | oafedulidis | Assigned to capsule by script |
| 21. Apr 2021 11:03:11 CEST | jreher | Updated box and position via API. |
| 05. Feb 2021 11:11:00 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:29:48 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 20:00:06 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:24:46 CET | jreher | Updated box and position via API. |
| 18. Jul 2019 10:27:21 CEST | spankonin | Updated APD batch assignment via API. |
| 09. Jul 2019 13:46:37 CEST | markus.moritz | |
| 05. Jul 2019 14:50:06 CEST | jreher | Updated APD location via API. |
| 24. Jun 2019 13:05:57 CEST | jgrochowski | Updated APD batch assignment via API. |
| 03. Jan 2019 00:12:08 CET | Tobias | Corrected dark current unit. |
| 12. Jan 2018 13:12:00 CET | Tobias | Imported from Hamamatsu datasheet. |