RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2420027543 - Archived data from Mon, 25. November 2019 17:13:01 CET


This is all the information about APD 2420027543. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2420027543
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2409026595/2420027543
Unit: #865 (barcode 1309009480)
Preamp: 4593
Current location: Bochum Box 27
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: B07
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.5 V
Dark current: 5.1 nA
   
Screening Logistics:  
Available: No
Storage Box: 27
Position in Box: 37
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 25. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:51:21 CET jreher Updated box and position via API.
03. Feb 2021 18:17:27 CET jreher Updated box and position via API.
11. Aug 2020 17:24:09 CEST jreher Updated APD characteristics via API.
13. Feb 2020 14:42:52 CET jreher Updated box and position via API.
27. Nov 2019 19:34:17 CET jreher Updated APD location via API.
25. Nov 2019 17:13:01 CET jreher Updated box and position via API.
17. Oct 2019 14:10:42 CEST tholtmann Assigned to unit by script
17. Oct 2019 13:56:57 CEST tholtmann Assigned to capsule by script
04. Jul 2019 11:09:54 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:26 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:21 CEST jreher Updated APD batch assignment via API.
25. Jan 2019 14:43:41 CET markus.moritz
03. Jan 2019 00:11:57 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:55 CET Tobias Imported from Hamamatsu datasheet.