Show Hamamatsu Avalanche Photo Diode 2419027425 - Archived data from Wed, 03. February 2021 18:17:12 CET
This is all the information about APD 2419027425. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2419027425 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | D05 |
| Break-through voltage: | 409 V |
| Voltage for Gain 100 (T=+25°C): | 380.8 V |
| Dark current: | 3.5 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 25 |
| Position in Box: | 40 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 16. Jan 2019 |
| Sent for analysis after irradiation: | 28. Jan 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 21. Jan 2019 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 22. Jan 2019 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 380.8217542 V T = -25 °C: 345.2556136 V |
| Voltage for Gain 150: | T = +20 °C: 388.6901971 V T = -25 °C: 352.5820829 V |
| Voltage for Gain 200: | T = +20 °C: 392.9946759 V T = -25 °C: 356.7551308 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.503013412 V-1 T = -25 °C: 4.561754733 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.343172117 V-1 T = -25 °C: 9.28823264 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 15.58807899 V-1 T = -25 °C: 15.55267737 V-1 |
| Break-through voltage: | T = +20 °C: 408.4193649 V T = -25 °C: 372.201044 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 27. Oct 2021 14:14:09 CEST | oafedulidis | Assigned to capsule by script |
| 28. Apr 2021 13:28:53 CEST | oafedulidis | Updated box and position via API. |
| 05. Feb 2021 10:51:05 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:17:12 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:23:51 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:33:56 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:12:52 CET | jreher | Updated box and position via API. |
| 04. Jul 2019 11:09:38 CEST | jreher | Updated APD location via API. |
| 12. Jun 2019 16:47:18 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 16:32:13 CEST | jreher | Updated APD batch assignment via API. |
| 28. Jan 2019 12:34:46 CET | markus.moritz | |
| 03. Jan 2019 00:11:54 CET | Tobias | Corrected dark current unit. |
| 12. Jan 2018 13:11:53 CET | Tobias | Imported from Hamamatsu datasheet. |