Subdetector specification:  
Serial: 2418027375
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D04
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 377.8 V
Dark current: 5.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 25
Position in Box: 9
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 28. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.6999225 V     T = -25 °C: 342.6105009 V
Voltage for Gain 150: T = +20 °C: 385.5213263 V     T = -25 °C: 349.9735283 V
Voltage for Gain 200: T = +20 °C: 389.911283 V     T = -25 °C: 354.1096131 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.720753761 V-1     T = -25 °C: 5.003038447 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.950015081 V-1     T = -25 °C: 9.762076133 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.05548199 V-1     T = -25 °C: 15.89288871 V-1
Break-through voltage: T = +20 °C: 405.47192 V     T = -25 °C: 369.0753148 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:51:01 CET jreher Updated box and position via API.
03. Feb 2021 18:17:08 CET jreher Updated box and position via API.
11. Aug 2020 17:23:44 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:33:53 CET jreher Updated APD location via API.
25. Nov 2019 17:12:50 CET jreher Updated box and position via API.
04. Jul 2019 11:09:36 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:15 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:10 CEST jreher Updated APD batch assignment via API.
28. Jan 2019 13:24:37 CET markus.moritz
03. Jan 2019 00:11:52 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:52 CET Tobias Imported from Hamamatsu datasheet.