RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2418027353 - Archived data from Wed, 03. February 2021 18:17:04 CET


This is all the information about APD 2418027353. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2418027353
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F14
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 381.2 V
Dark current: 7.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 24
Position in Box: 38
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 25. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.0449483 V     T = -25 °C: 345.5786915 V
Voltage for Gain 150: T = +20 °C: 388.8778351 V     T = -25 °C: 353.0022702 V
Voltage for Gain 200: T = +20 °C: 393.2469835 V     T = -25 °C: 357.1744544 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.692062175 V-1     T = -25 °C: 4.678590316 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.888117806 V-1     T = -25 °C: 8.971520819 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.08288702 V-1     T = -25 °C: 16.29313619 V-1
Break-through voltage: T = +20 °C: 408.5403335 V     T = -25 °C: 372.0170638 V
   
Notes:


Version history

Time Author Change comment
29. Mar 2022 12:39:59 CEST oafedulidis Assigned to capsule by script
30. Aug 2021 14:07:59 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:50:57 CET jreher Updated box and position via API.
03. Feb 2021 18:17:04 CET jreher Updated box and position via API.
11. Aug 2020 17:23:40 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:33:44 CET jreher Updated APD location via API.
25. Nov 2019 17:12:47 CET jreher Updated box and position via API.
04. Jul 2019 11:09:30 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:14 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:08 CEST jreher Updated APD batch assignment via API.
25. Jan 2019 12:24:49 CET markus.moritz
03. Jan 2019 00:11:52 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:52 CET Tobias Imported from Hamamatsu datasheet.