RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2417027286 - Archived data from Wed, 03. February 2021 18:16:55 CET


This is all the information about APD 2417027286. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2417027286
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D04
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.9 V
Dark current: 4.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 23
Position in Box: 13
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 25. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.0312224 V     T = -25 °C: 345.7421207 V
Voltage for Gain 150: T = +20 °C: 388.811523 V     T = -25 °C: 353.1470853 V
Voltage for Gain 200: T = +20 °C: 393.1244663 V     T = -25 °C: 357.304705 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.17446757 V-1     T = -25 °C: 5.598526183 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.815479914 V-1     T = -25 °C: 9.718046595 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.03249141 V-1     T = -25 °C: 14.07937718 V-1
Break-through voltage: T = +20 °C: 408.2719148 V     T = -25 °C: 372.4642269 V
   
Notes:


Version history

Time Author Change comment
29. Mar 2022 12:37:26 CEST oafedulidis Assigned to capsule by script
03. May 2021 15:19:53 CEST oafedulidis Updated box and position via API.
26. Apr 2021 14:28:00 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:50:47 CET jreher Updated box and position via API.
03. Feb 2021 18:16:55 CET jreher Updated box and position via API.
11. Aug 2020 17:23:28 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:33:32 CET jreher Updated APD location via API.
25. Nov 2019 17:12:41 CET jreher Updated box and position via API.
04. Jul 2019 11:09:20 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:07 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:02 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:12:07 CEST jreher Updated APD batch assignment via API.
25. Jan 2019 12:07:44 CET markus.moritz
03. Jan 2019 00:11:49 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:51 CET Tobias Imported from Hamamatsu datasheet.