Show Hamamatsu Avalanche Photo Diode 2415027159 - Archived data from Wed, 03. February 2021 18:16:38 CET
					This is all the information about APD 2415027159. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2415027159 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | Bochum | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | C10 | 
| Break-through voltage: | 406 V | 
| Voltage for Gain 100 (T=+25°C): | 377 V | 
| Dark current: | 4.7 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 21 | 
| Position in Box: | 20 | 
| EP1 batch: | none | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | none | 
| Position in grid: | none | 
| Arrival for irradiation: | 16. Jan 2019 | 
| Sent for analysis after irradiation: | 25. Jan 2019 | 
| Return for assembly: | none | 
| Irradiation: | |
| Date: | 21. Jan 2019 | 
| Dose used: | 37 Gy | 
| Temperature: | 20 °C | 
| Position: | none | 
| Bias voltage: | none | 
| Annealing: | |
| Date: | 22. Jan 2019 | 
| Temperature: | 80 °C | 
| Duration: | 48 h | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 377.2893569 V T = -25 °C: 342.1244824 V | 
| Voltage for Gain 150: | T = +20 °C: 385.0886058 V T = -25 °C: 349.4879024 V | 
| Voltage for Gain 200: | T = +20 °C: 389.4573596 V T = -25 °C: 353.6316503 V | 
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.726313646 V-1 T = -25 °C: 4.709523129 V-1 | 
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.104393667 V-1 T = -25 °C: 9.231320865 V-1 | 
| Gain/Voltage slope at M = 200: | T = +20 °C: 15.41866089 V-1 T = -25 °C: 15.88450354 V-1 | 
| Break-through voltage: | T = +20 °C: 405.1695028 V T = -25 °C: 368.8790978 V | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 05. Feb 2021 10:50:30 CET | jreher | Updated box and position via API. | 
| 03. Feb 2021 18:16:38 CET | jreher | Updated box and position via API. | 
| 11. Aug 2020 17:23:08 CEST | jreher | Updated APD characteristics via API. | 
| 27. Nov 2019 19:33:10 CET | jreher | Updated APD location via API. | 
| 25. Nov 2019 17:12:32 CET | jreher | Updated box and position via API. | 
| 04. Jul 2019 11:09:03 CEST | jreher | Updated APD location via API. | 
| 12. Jun 2019 16:46:58 CEST | jreher | Updated APD batch assignment via API. | 
| 12. Jun 2019 16:31:53 CEST | jreher | Updated APD batch assignment via API. | 
| 12. Jun 2019 15:10:20 CEST | jreher | Updated APD batch assignment via API. | 
| 25. Jan 2019 12:24:58 CET | markus.moritz | |
| 03. Jan 2019 00:11:46 CET | Tobias | Corrected dark current unit. | 
| 12. Jan 2018 13:11:49 CET | Tobias | Imported from Hamamatsu datasheet. |