RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2414027088 - Archived data from Fri, 27. August 2021 10:30:48 CEST


This is all the information about APD 2414027088. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2414027088
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G05
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 379.6 V
Dark current: 4.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 238
Position in Box: 30
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.2058368 V     T = -25 °C: 344.7879477 V
Voltage for Gain 150: T = +20 °C: 387.9970825 V     T = -25 °C: 352.1587558 V
Voltage for Gain 200: T = +20 °C: 392.3610299 V     T = -25 °C: 356.3142174 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.739077674 V-1     T = -25 °C: 4.839091352 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.190786943 V-1     T = -25 °C: 9.554475009 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.5528192 V-1     T = -25 °C: 14.58920347 V-1
Break-through voltage: T = +20 °C: 408.0060768 V     T = -25 °C: 371.5555612 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:15:44 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 10:30:48 CEST oafedulidis Updated box and position via API.
26. Apr 2021 15:22:35 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:50:20 CET jreher Updated box and position via API.
03. Feb 2021 18:16:30 CET jreher Updated box and position via API.
11. Aug 2020 17:22:56 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:32:58 CET jreher Updated APD location via API.
25. Nov 2019 17:12:26 CET jreher Updated box and position via API.
04. Jul 2019 11:08:54 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:53 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:48 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:10:00 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:11:44 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:48 CET Tobias Imported from Hamamatsu datasheet.