RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2414027032 - Archived data from Fri, 05. February 2021 10:50:12 CET


This is all the information about APD 2414027032. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2414027032
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B05
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.1 V
Dark current: 7.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 19
Position in Box: 3
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 25. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.8773501 V     T = -25 °C: 348.1971751 V
Voltage for Gain 150: T = +20 °C: 391.699875 V     T = -25 °C: 355.6533203 V
Voltage for Gain 200: T = +20 °C: 396.056044 V     T = -25 °C: 359.8525582 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.529583327 V-1     T = -25 °C: 4.663414788 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.766846572 V-1     T = -25 °C: 9.160299807 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.77750789 V-1     T = -25 °C: 15.6551693 V-1
Break-through voltage: T = +20 °C: 410.7640065 V     T = -25 °C: 374.6743659 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:21:08 CEST oafedulidis Assigned to capsule by script
17. May 2021 09:15:34 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:50:12 CET jreher Updated box and position via API.
03. Feb 2021 18:16:22 CET jreher Updated box and position via API.
11. Aug 2020 17:22:45 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:32:46 CET jreher Updated APD location via API.
25. Nov 2019 17:12:21 CET jreher Updated box and position via API.
04. Jul 2019 11:08:45 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:48 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:43 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:09:35 CEST jreher Updated APD batch assignment via API.
25. Jan 2019 14:18:51 CET markus.moritz
03. Jan 2019 00:11:42 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:47 CET Tobias Imported from Hamamatsu datasheet.