Show Hamamatsu Avalanche Photo Diode 2414027023 - Archived data from Tue, 11. August 2020 17:22:44 CEST


This is all the information about APD 2414027023. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2414027023
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E04
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.3 V
Dark current: 6.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 18
Position in Box: 26
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 28. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.8406134 V     T = -25 °C: 346.0773344 V
Voltage for Gain 150: T = +20 °C: 389.7019713 V     T = -25 °C: 353.5159765 V
Voltage for Gain 200: T = +20 °C: 394.0840943 V     T = -25 °C: 357.7067929 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.515865116 V-1     T = -25 °C: 4.694298035 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.611096922 V-1     T = -25 °C: 9.182236768 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.43143151 V-1     T = -25 °C: 15.78381249 V-1
Break-through voltage: T = +20 °C: 409.6885851 V     T = -25 °C: 373.1594412 V
   
Notes:


Version history

Time Author Change comment
26. Apr 2021 15:21:43 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:50:09 CET jreher Updated box and position via API.
03. Feb 2021 18:16:18 CET jreher Updated box and position via API.
11. Aug 2020 17:22:44 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:32:38 CET jreher Updated APD location via API.
25. Nov 2019 17:12:20 CET jreher Updated box and position via API.
04. Jul 2019 11:08:40 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:47 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:42 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:09:34 CEST jreher Updated APD batch assignment via API.
28. Jan 2019 12:10:55 CET markus.moritz
03. Jan 2019 00:11:41 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:47 CET Tobias Imported from Hamamatsu datasheet.