RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2413026965 - Archived data from Tue, 30. March 2021 15:06:08 CEST


This is all the information about APD 2413026965. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2413026965
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: In transit to Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D13
Break-through voltage: 418 V
Voltage for Gain 100 (T=+25°C): 388.7 V
Dark current: 7.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 18
Position in Box: 1
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
16. Apr 2021 22:09:53 CEST jreher Updated APD characteristics via API.
30. Mar 2021 15:06:08 CEST jreher Updated APD batch assignment via API.
05. Feb 2021 10:50:03 CET jreher Updated box and position via API.
03. Feb 2021 18:16:13 CET jreher Updated box and position via API.
03. Feb 2021 18:06:44 CET jreher Updated APD location via API.
28. Nov 2019 10:38:52 CET jreher Updated APD location via API.
27. Nov 2019 19:32:35 CET jreher Updated APD location via API.
25. Nov 2019 17:12:16 CET jreher Updated box and position via API.
04. Jul 2019 11:08:37 CEST jreher Updated APD location via API.
03. Jan 2019 00:11:40 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:46 CET Tobias Imported from Hamamatsu datasheet.