RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2412026828 - Archived data from Wed, 03. February 2021 18:16:02 CET


This is all the information about APD 2412026828. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2412026828
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D06
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 379.9 V
Dark current: 7.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 16
Position in Box: 45
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 13. Dec 2018
Return for assembly: none
   
Irradiation:  
Date: 07. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.306955 V     T = -25 °C: 344.9241568 V
Voltage for Gain 150: T = +20 °C: 388.1724812 V     T = -25 °C: 352.3289345 V
Voltage for Gain 200: T = +20 °C: 392.5799164 V     T = -25 °C: 356.4992323 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.697070592 V-1     T = -25 °C: 4.797990258 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.077822257 V-1     T = -25 °C: 9.486218997 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.76364273 V-1     T = -25 °C: 14.6077251 V-1
Break-through voltage: T = +20 °C: 408.3450478 V     T = -25 °C: 371.8902624 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:23:24 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 10:31:48 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:49:52 CET jreher Updated box and position via API.
03. Feb 2021 18:16:02 CET jreher Updated box and position via API.
11. Aug 2020 17:22:25 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:32:16 CET jreher Updated APD location via API.
25. Nov 2019 17:12:10 CET jreher Updated box and position via API.
04. Jul 2019 11:08:24 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:38 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:33 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:09:08 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:11:36 CET Tobias Corrected dark current unit.
13. Dec 2018 13:37:34 CET markus.moritz
16. Nov 2018 15:39:29 CET markus.moritz
12. Jan 2018 13:11:44 CET Tobias Imported from Hamamatsu datasheet.