Show Hamamatsu Avalanche Photo Diode 2410026711 - Archived data from Wed, 12. June 2019 16:31:26 CEST
This is all the information about APD 2410026711. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2410026711 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | unknown |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | C02 |
| Break-through voltage: | 412 V |
| Voltage for Gain 100 (T=+25°C): | 383.5 V |
| Dark current: | 4.2 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 15 |
| Position in Box: | 16 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 12. Nov 2018 |
| Sent for analysis after irradiation: | 13. Dec 2018 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 07. Dec 2018 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 10. Dec 2018 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 29. Apr 2021 17:03:50 CEST | oafedulidis | Assigned to capsule by script |
| 16. Feb 2021 12:28:45 CET | jreher | Updated box and position via API. |
| 05. Feb 2021 10:49:40 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:15:50 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:22:10 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:32:03 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:12:04 CET | jreher | Updated box and position via API. |
| 04. Jul 2019 11:08:14 CEST | jreher | Updated APD location via API. |
| 12. Jun 2019 16:46:31 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 16:31:26 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 15:03:45 CEST | jreher | Updated APD batch assignment via API. |
| 03. Jan 2019 00:11:33 CET | Tobias | Corrected dark current unit. |
| 13. Dec 2018 11:44:33 CET | markus.moritz | |
| 23. Nov 2018 14:18:12 CET | markus.moritz | |
| 12. Jan 2018 13:11:42 CET | Tobias | Imported from Hamamatsu datasheet. |